500 W Fiber to Free Space Isolator
description1
Specifications
Optical Parameter |
Unit |
Value |
Operating Wavelength (λc) |
nm |
1064 ± 30 |
Max. Insertion Loss at 23 ℃ , at λc |
dB |
0.4 |
Typ. Isolation at 23 ℃ , at λc |
dB |
38 |
Min. Isolation at 23 ℃ , at λc |
dB |
30 |
Min. Isolation at all temperature, at λc |
dB |
20 |
Min. Return Loss |
dB |
50 |
Nominal Output Beam Diameter (1/e²)¹ |
mm |
2.0 ± 0.2 |
Beam Circulatory |
% |
> 90 |
M² Degradation |
% |
< 10 |
Max. Average Optical Power |
W |
500 |
Max. Peak Power for ns pulse |
kW |
50 |
Beam offset |
mm |
± 0.5 |
Pointing Error |
mrad |
2.5 |
Astigmatism |
Zʀ |
< 0.25 |
Fiber and Conditions |
Unit |
Value |
Fiber Type |
- |
specified by ordering info |
Cooling |
- |
Water |
Water Quality |
- |
Purified or Distilled Water |
Flow Rate |
L / min |
1.5 - 2.5 |
Water Pressure |
Mpa |
≤ 0.3 |
Water Temperature |
- |
≥ 5 °C above Dew Point |
Water PH Value |
- |
Temperature |
Reverse Power Handling |
W |
5.6 - 7.9 |
Operating Temperature |
℃ |
200 W Continuous |
Storage Temperature |
℃ |
+ 10 to + 50 - 10 to + 60 |
Optional beamexpander available for different beam diameter. | ||
Package Dimensions